Device
Connect
Control
Status
Module
| Connection status | |
| Firmware option | |
| Firmware version | |
| Up time | |
| Serial number | |
| State | |
| Model | 
Ethernet
| MAC address | |
| Status | |
| IP | |
| Netmask | |
| Gateway | 
Wi-Fi Access Point
| MAC address | |
| Status | |
| SSID | |
| IP | |
| Netmask | 
Wi-Fi Client
| MAC address | |
| Status | |
| SSID | |
| IP | |
| Netmask | |
| Gateway | 
Settings
Settings I/O
Security
Trigger security
If enabled, codes submitted via Wi-Fi or Ethernet will require the following password to be entered before the code itself
i.e., `<ESC>p0` → `pass<ESC>p0`
        | Enable trigger password | |
| Trigger password | 
     | 
    
Site login credentials
| Username | |
| Password | 
     | 
    
| Confirm password | 
     | 
    
Trigger
| Send response on open | Sends `0x14 0x00 0x00 0x0f` | |
| Send response on close | Sends `0x10 0x00 0x00 0x0f` | |
| Invert status pin | Enable this if 'state' in Status is 'open' when it should be 'closed' | |
| Relay on-time | ||
| Relay trigger voltage | ||
| Minimum relay trigger voltage (mV) | Relay charges up to "Relay trigger voltage" but will allow triggering at this voltage. Reduces minimum charge times, but may cause misfires if set too low. 0 = Determined automatically.  | 
    |
| Send message on TCP connection | Sends "Password:" when connecting via TCP | 
Networking
| Enable mDNS | |
| mDNS hostname | |
| TCP port | 
Ethernet
| Enabled | |
| Connection type | 
Static IP
| Static IP | |
| Netmask | |
| Gateway | |
| Primary DNS | |
| Secondary DNS | 
Wi-Fi Access Point
| Enabled |      
            On startup the hotspot will be live for 10 minutes
         
     | 
    |
| SSID | ||
| Password | 
     | 
    |
| IP | ||
| Netmask | 
Wi-Fi Client
| Enabled | |
| SSID | |
| Password | 
     | 
    
| Authentication mode | |
| Connection type | 
Static IP
| Static IP | |
| Netmask | |
| Gateway | |
| Primary DNS | |
| Secondary DNS | 
USB
| USB Type |      
        Warning! If USB type is set to Host, you will no longer be able to configure the device via USB.
     
 | 
    
Command codes
    Below are configurable command codes and their associated actions.
    
        e.g., entering '<ESC>p0' will trigger relay 1.
    Non-printable characters are entered using their control code representation.
    e.g., '<ESC>' or '<0x1B>'
| Code | Echo | Trigger 1 | Trigger 2 | Remove | 
|---|---|---|---|---|
RFID Reader
| Enabled | |
| Tag Event Report Format | |
| Read Power (dBm) | |
| Write Power (dBm) | |
| Session | 
Virtual Read Zones
| Read Zone ID | Antennae | Start delay (ms) | ON duration (ms) | Remove | 
|---|---|---|---|---|
MQTT
    When MQTT is enabled, the reader will connect to the broker on URI: {transport scheme}://{hostname}:{port}/{path}
        | Enabled | ||
| Transport Scheme | ||
| Broker Hostname | ||
| Broker Port | ||
| Broker Path | ||
| Client ID | ||
| Username | ||
| Password | 
     | 
    |
| Persistent Session | Enables persistent session by setting cleanSession flag to false | 
Heartbeat
| Enabled | ||
| Heart Beat Interval (s) | 0 = No heart beat | |
| Heartbeat Report Topic | Reader will publish heartbeats to this topic | 
MQTT Topics
| Command Topic | Reader will subscribe to this topic to listen for commands | |
| Active RZ Report Topic | Reader will publish all active transmitting read zones upon change | |
| Error Report Topic | Reader will publish error reports to this topic | |
| Tag Event Report Topic | Reader will publish tag event reports to this topic | 
You have unsaved changes!
      
      Update Firmware
        Instructions:
        
      
      - Download the new firmware from an official UMD source
 - M320AU (USB)
https://www.umd.com.au/m320/firmware_M320AU.bin - M320AW (Wi-Fi)
https://www.umd.com.au/m320/firmware_M320AW.bin - M320AE (Ethernet)
https://www.umd.com.au/m320/firmware_M320AE.bin - Click Choose file, and select the downloaded firmware
 - Click Upload file
 - Wait for the firmware to finish uploading to the module
 - Check the firmware version in Status matches the downloaded firmware's version
 
Documentation
Please note that accessing the following links requires an internet connection.M320 Universal Trigger - Technical Manual